B™ Self-Clinching Blind Fasteners
Installation
PDF page 18 · PEM Fastener Catalogue
- Prepare properly sized mounting hole in the sheet. Do not perform any secondary operations such as deburring.
- Place the barrel of the fastener into the anvil hole and place the mounting hole (preferably the punch side) over the shank of the fastener.
- With the installation punch and anvil surfaces parallel, apply squeezing force until the flange contacts the mounting sheet. The sketch at the right indicates suggested tooling for applying these forces.
Installation drawing callouts: Punch; Anvil; Chamfer on anvil .010" +.005 −.000 / 0.25 mm +0.13 x 45˚ Nom.; B* + .006" / 0.15 mm, + .003" / 0.08 mm; L* +.06" / 1.5 mm MIN. * For "B" and "L", see page 17.
PEMSERTER® Installation Tooling
| Type | Thread Code | Anvil Part Number | Punch Part Number |
|---|---|---|---|
| B/BS | 440/M3 | 975200001 | 975200048 |
| B/BS | 632 | 975200002 | 975200048 |
| B/BS | 832/M4 | 975200003 | 975200048 |
| B/BS | 032/M5 | 975200004 | 975200048 |
| B/BS | 0420/M6 | 975200005 | 975200048 |
Installation Notes
- For best results we recommend using a Haeger® or PEMSERTER® machine for installation of PEM® self-clinching fasteners. Please check our website for more information.
- Visit the Animation Library on our website to view the installation process for this product.