AISCAISC 360-22
Formulas

Formulas: Compression Flange Local Buckling

PDF page 129 · AISC 360-22

Equation F5-7

Mn=RpgFcrSxcM_{n}=R_{p g} F_{c r} S_{x c}

Equation F5-8

Fcr=Fy(0.3Fy)(λλpfλrfλpf)F_{c r}=F_{y}-\left(0.3 F_{y}\right)\left(\frac{\lambda-\lambda_{p f}}{\lambda_{r f}-\lambda_{p f}}\right)

Equation F5-9

Fcr=0.9Ekc(bf2tf)2F_{c r}=\frac{0.9 E k_{c}}{\left(\frac{b_{f}}{2 t_{f}}\right)^{2}}

where

kc=4h/tw and shall not be taken as less than 0.35 nor greater than 0.76 for calculation purposes λ=bfc2tfc\begin{aligned} k_{c} & =\frac{4}{\sqrt{h / t_{w}}} \text { and shall not be taken as less than } 0.35 \text { nor greater than } 0.76 \text { for calculation purposes } \\ \lambda & =\frac{b_{f c}}{2 t_{f c}}\end{aligned}

λpf=λp\lambda_{p f}=\lambda_{p}, the limiting width-to-thickness ratio for a compact flange as defined in Table B4.1b

λrf=λr\lambda_{r f}=\lambda_{r}, the limiting width-to-thickness ratio for a noncompact flange as defined in Table B4.1b

Formula 4

λpf=λp\lambda_{p f}=\lambda_{p}, the limiting width-to-thickness ratio for a compact flange as defined in Table B4.1b

λpf=λp\lambda_{p f}=\lambda_{p}

Formula 5

λrf=λr\lambda_{r f}=\lambda_{r}, the limiting width-to-thickness ratio for a noncompact flange as defined in Table B4.1b

λrf=λr\lambda_{r f}=\lambda_{r}