Formulas
Formulas: Tie Bar Requirement
PDF page 163 · AISC 360-22
Formula 1
Tie bars shall have spacing no greater than 1.0 times the wall thickness, . The tie bar spacing to plate thickness ratio, , shall be limited as follows:
Equation II-5M
Equation II-6
where
effective diameter of the tie bar, in. (mm)
largest clear spacing of the ties, in. (mm)
- = thickness of plate, in. (mm)
thickness of composite plate shear wall, in. (mm)