Formulas
Formulas: Local Buckling
PDF page 133 · AISC 360-22
Equation F8-2
Equation F8-3
where
(F8-4)
= design wall thickness of HSS member, in. (mm)
PDF page 133 · AISC 360-22
where
DFcr= outside diameter of round HSS, in. (mm) =(D)0.33E (F8-4)
t = design wall thickness of HSS member, in. (mm)